M302 p1. Expected behavior: The Unload should ignore the temperature on the Hotend and do its thing. M302 p1

 
 Expected behavior: The Unload should ignore the temperature on the Hotend and do its thingM302 p1 g

Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. The belts are not over tight. Other possible causes are a bad stepper motor or cable. 1 active and standby temperatures to 0C. g. Duet Web Control makes it easy to upload, edit and create new macros. 1 Reply Last reply Reply Quote 0. retraction temperature 90. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. Send T0 in the gcode console and check the buttons again. M302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. g. Extrude a little more filament: G1 E20 F200; Measure as accurately as you can using a rule between your marks. Now with Marilin 2. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. M302 P0. I made my own slicer for the concrete printer, but for some reason the layer change is not detected, so my "Last Layer Time" is not updated. Repetier 1. dmould. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. @dc42 That doesn't seem to work. : till no luck with Extrusion Control jogging buttons. 00°C/sec. droftarts administrators @flyscha last edited by . Ok i did the test you asked and did the commands thru the gcode console and with tool 0 on drive 0 selected when i give the G1 E20 F5 command i get a slight twitch on the motor shaft but the shaft spins freely with little to no resistance on the shaft i switched the motor cable to the drive 1 and set my config_g to use tool 0 drive one and with tool 0. Viko. 1. Other possible causes are a bad stepper motor or cable. The code sends commands to an Octoprint instance. HI again, what I'm doing wrong, the extruder buttons in DWC won't be gray, its grayed out. Cannot get extruder motor to respond. g macro is;Autoload filament macro. Last edit at 01/11/2023 01:58AM by Dust. Part Type: Rear Main Seals. Does the motor turn? If yes, then probably it’s not having enough power to push the filament through the nozzle. Set the temperature (and enable) using. M117 Let's make some filament!;Turn on fan;M106. 15mm Nozzle (Pink)The punch slide unit is driven by the punch shift motor (M302). Grabbed a Ramps 1. 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. Macros also allow for naming gcodes with easier to remember names. Fan1 configured in thermostatic mode by default. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. 0C. 2"x12" backing boards 2"x4" studs 16. Our innovative life science, applied science, and clinical products are now found under the Applied Biosystems™, Invitrogen™, Gibco™, Ion Torrent™, and Molecular Probes™ brands. M302 P1 will disable the temperature check that disables the extruder when the nozzle is cold. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. . Ok I will try the. These are commands that one may enter into the OctoPrint terminal tab. g ; go to purge bucket. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. is not colored in WebControl as in the example screenshots i saw. It was type 5 in marlin. g and resume. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. M302 P1 ; allow cold extrusion. CryptoThis topic has been deleted. Large delta printer [miscsolutions. Hello. : Heater 1 fault: temperature rising too slowly: expected 2. ; Tool definitions M563 P0 D0 H1 ; Define tool 0 M302 P1 ; Allow cold extrusion M140 H-1 ; Bed Off;Misc M83 ; Set extruder to relative mode M302 P1 ; Allow cold extrudes. M302 works fine in a starting script or sent via console. g. 13. To test for this, with the power off swap the E0 connector on the Duet with another one e. gpIn[0]. Features solid metallic core with. Send T0 in the gcode console and check the buttons again. 00°C/sec. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. I would be very gratefull for any help. Trying to figure out why I can't run my extruder. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. I made a clay extruder for my printer. 23". M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled. There is a web tool for this here which can make this easier for configuring another printer. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. 36°C/sec measured -0. M302 P1 ; allow cold extrusion. 455513e-8Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. I have almost everything working: Temp sensors All the axis drives including 4-Z steppers. extrusion temperature 160. yello3d. M98 Ppurge_bucket . Well broadly speaking I think this is the basis for the new UM3 bed probing, the probe presses on the glass which triggers a capacitative sensor underneath. A typical piece of GCode sent to a machine running RepRapFirmware might look like this (The meaning of these codes (and more) is. I would be very gratefull for any help. Some common uses…. Edit. 9 Windows 10 I am using a macro in reprapFirmware to pause the print for a certain length of time after evey layer. M584 X0. Make anothe mark on the filament right where it leaves the fitting. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. 1 Reply Last reply Reply Quote 0. Extrusion Control in DWC unavailable, even after M302 P1. 26" ; configure active-high endstop for low end on Y via pin null M574 Z1 S1 P"!P1. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. Both Agisoft and Pix4d do some weird color smoothing that makes the meshes much less crisp looking. G92 X0 Y0 Z0 ; set current position to {X=0,Y=0,Z=0} G92 E0 ;zero the extruded length. plan view. Sometimes it moves once but doesn't execute the other commands. Wood filament wont extrude / print below 200deg. Good morning. @patel said in how to change homing sequence: corexy printer setup how to change sequence homing x,y i am using M3D promega and i need to change sequence first y axis home after x axis manual working fine by hand trigger switch x limit and y limit See h. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. @deckingman please find ;Cold extrusion M302 P1 ; allow cold extrusion ; Drives M569 P0 S1 ; physical drive 0 goes forwards M569 P1 S1 ; physical drive 1 goes forwards M569 P2 S1. Re: Extrude without a Hotend May 04, 2017 11:25PM. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:Hey all, my melzi finally died. Step 6. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysG-code for the 4th axis of the tangential knife after a slight modification {ASCI "conversion " (" to ";" and "A" to "E") allows you to run the code in the Marlin software. US is first line imaging test after clinical triage; MRI only if US is equivocal and. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x Digital. Direct drive: Remove your nozzle, hotend, or extruder. CryptoI did try a cold extrude M302 P1. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by… Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. Re: Extrude without a Hotend. . g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. 3 Then I think you should config the BLTouch differently: Have you read this bit, "Software setup (. elvoron mr approval drawing & signature required. Can not get E0 to extrude, M302 P1 = still grey buttonsI am using Cura to slice a simple cube. 30 caliber carbine cartridge from 15-round and 30-round detachable box magazines. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. yello3d. Business, Economics, and Finance. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. 3 ; Filter. This topic has been deleted. . one immediately before X). If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Click to Enlarge. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. CryptoM302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears. La commande G-code M302 P1 permet l'extrusion a froid. Hi all, It turned out to be the end-stops micro switches causing the board to lose connection. 12/28/2022, 7:25:14 PM M302 Cold extrusion is allowed (use M302 P0 to forbid it) 12/28/2022, 7:25:05 PM M302 P1 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. 8 is far too low for two reasons: 1. droftarts administrators @flyscha last edited by . Technical Explanation 1. How can I make reprap firmware print without any heater or temperature sensors? Does it have a fake heater that I can make always return 200c or something to make the firmware extrude with a cold extruder, or even wi. But if I use g28 to home the axis, it then will not work. Viko. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. G1 E500 F300. After you’re done calibrating Esteps, re-enable cold extrusion temperature checking with M302 P0 As has been mentioned, heating the nozzle also works. Other possible causes are a bad stepper motor or cable. Reply Quote. Re: How can I move E steppers? January 11, 2023 02:36AMJust to bed the gears and drive cable in. g to make the process as painless as possible. (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. Extruding some filament with M302 P1 enabled (cold extrusion) with bowden out of hotend Extruding some filament with hotend at required temperature Printing a test print. 36°C/sec measured -0. Send M302 P1 to allow Cold extrusion; Send M600 T1 to initiate Filament swap; Follow the Instructions on the Screen. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. g. However,. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. 8. I used to use "Pronterface" for that. Can you share output of M122 command and try cold extrude using M302 P1 it'll enable extrude button. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. Now with Marilin 2. May 04, 2017 11:25PM. Tried setting up the extruder on drive 4 then on drive 3. Surely there must be a way to do cold extrusion (no heater, no thermistor) for those of us who don't want to extrude hot filament?M302 P1; Allow cold extrude : T0; select tool 0: G10 P0 S180; heat tool 0 to 180 and wait: M116 P0: G10 P0 S120; cool tool 0 to 120 and wait: M116 P0: G1 E-20 F300; retract 20mm at 5mm/sec; change the following E values to suit your Bowden Tube length : G1 E-50 F600; retract another 50mm at 10mm/sec: G1 E-200 F3000; retract another 150mm at. Compatible with the FlightHub 2 cloud platform and DJI Dock to achieve cloud collaboration and. Slic3r 1. I drive them with: M906 X1000 Y1000 Z1000 E900 I30 One of the steppers starts skipping since some days and I'm unable to find the reason. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). Users of single-extruder machines often put a T0 command at the end of config. Edit the M305 P1 command in file sys/config. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. Set fan 0 value, PWM signal inversion and frequency. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Large delta printer [ miscsolutions. Last edit at 01/11/2023 01:58AM by Dust. 294060 INTRODUCTION INTRODUCTION This manual contains information for post processor to create EIA/ISO program according to the machine. . Put this as first line of your custom gcode. 5mm/sec echo "Done" M82 ; set extruder to abs modeM302 P1 ; allow cold extrusion. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. Ok I will try the bugfix branch with the config files you provided! G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C I need to print some PCL filament, which melts optimally at 100 C°. 2 ; interpolate mbl probesG29 P3. after turning off cold hotend detection with M302 P1. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. G4 S1 ; wait for one second. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. @jfavre said in Extruder motor not working. g. Crypto‘M302 P1 ; disable cold extrusion checking’ 2. M302 P1 disables the cold extrude safety. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. And now even Col Extrusion M302 P1 is generating errors. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. And, for swapping purposes, don't forget the extruder motor/cable/port. 5 and 1. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. The printer functions and works as a normal syringe printer and is compatible with the Lulzbot Cura slicer software. . PROMEGA I have installed a BL Touch clone and it works with the direct commands. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. g. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Still no luck with Extrusion Control jogging buttons. So when i home it, x and y go to 225 and z goes to 0. . 0C, min. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wM302 P1 ; allow cold extrusion. G28: home all axes. : till no luck with Extrusion Control jogging buttons. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. The extruder port might not actually be dead - Marlin has an idiotic function turned on by default that prevents extruder movement if the hotend is not up to temperature. 5 fans I have it doing all zeroing and even bed tramming! Awesome to see it tram a skewed-. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. 155 5. It's simple. Direct drive: Remove your nozzle,. For firmware versions 1. 03) ; executed by the firmware on start-up ; ; generated by RepRapFirmware Configuration Tool v2. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. Now I would like the printer to pause a print when the printer is running out of clay using an mechanical endstop. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. It should be possible to make a Gcode file in a text. . Here is my diagnostic file and my config. 0. Don't disable the thermal runaway protection. 00°C/sec When you try to heat does the LED near the heater terminal actually turn on? Can. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. Other possible causes are a bad stepper motor or cable. Deactivate with "M106 P1 H-1". Items 1 - 36 of 42. 16 07:24. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?We are using two different kinds of motors, but for the Z and E we are using we are using Nema 23 bipolar 2. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. Connector for the extruder is plugged into second connection (i. Re-enable with. 042". My request is to add a connection to the Marlin firmware as it is done in program "LaserGRBL" Your GRBL_Plotter program is very good, adding this function would make it even. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. zip. 06. I can't help you with fans on RADDS, but "Attempting to extrude with no tool selected" means just that. wordpress. I have a Voron v0 (CoreXY) with LDO 14HS20-1504S for X and Y. 7mm, the output contact is engaged @ about 0. g ; Unload to above y-splitter. 2 E1. 8Hz when using P4. This manual can be used as an EIA/ISO programming manual. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. @Phaedrux @dc42 @T3P3Tony. "M302 P1" tells the firmware it's ok to extrude though the hotend is cold. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m),. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. 2. extrusion temperature 160. 3, Speed 100% M106 P1 S0 I0 F4 H-1 L0. Other possible causes are a bad stepper motor or cable. g. the X motor. 0. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. Only users with topic management privileges can see it. I used to use "Pronterface" for that. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Other possible causes are a bad stepper motor or cable. La commande G-code M302 P1 permet l'extrusion a froid. 2. I am at a loss for next step. However, I can't get the servo running with the new firmware. ; Configuration file for Duet WiFi (firmware version 2. Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. Sending T0 initiates the heater and then faults out. 3 mm and released @ about 0. M302 P1 ; enable cold extrusion. 36°C/sec measured -0. Even I set M302 P1, the extruder control panel can't be use. 00 B0 M665 H100 TO. Re: How can I move E steppers? January 11, 2023 02:36AMFailure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. When I try to run the extruder (for example G1 E1) I make sure to allow cold extrusion (M302 P1). Make sure you clean out the heatblock and refit the nozzle properly, hot tightening it, etc. 3 E40 ; set drive mapping. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. I read up on the on "Connecting endstop switches - What might go wrong" and then I corrected the wiring and all is good with that. droftarts administrators @flyscha last edited by . I can put a dummy value on the T0 to verify the good functioning of the Titan. The macro folder can divided into sub directories to more easily organise your macros by type. I reduced. 0 S1 ; physical drive 1. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. g . Extrusion Control in DWC unavailable, even after M302 P1. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. The prototype was outsourced to Oshpark. DWC / Duet will sit and wait until the +3. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. So when i home it, x and y go to 225 and z goes to 0. g at here G91 ; relative positioning G1 Z5 F6000 S2 <--(problem is here, remplace S2 by H2) ; lift Z relative to current position G90. 0. I use duet wifi version 1. M302_P1_COLD_E. 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. the 0, 1,2 drivers still work fine. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Re-enable with. 2 the M302 P1 command doesn't help to allow the cold extrusion anymore. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. the X motor connector. gco] Select SD file M23 filename. Only users with topic management privileges can see it. I have a setup similar to the ANET A8. Set the temperature (and. the X motor. Now all the other axis are moving as supposed but the extruder ones are not. M302. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. The problem is that the G1 code runs only once, no matter what I put after the L. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. Tried M302 P1 four times. Macros also allow for naming gcodes with easier to remember names. 455513e-8@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsBusiness, Economics, and Finance. When tfreeN is called, filament is retracted above the y-splitter. M950 F1 C"fan1" Q500 ; create fan 1 on pin fan1 and set its frequency. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Orange - unload button is pressed (only when filament is present) Please note the filament sensing button used here is not a standard TACT switch. She said the item was unless to me meatbagI have a duex5 attached to a Duet Wifi with firmware 2. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)You need to edit homeall. Reply Quote. Click to Enlarge. It was type 5 in marlin. 2 Firmware:3. Don't expect G0 or G1 to make it move, when not homed. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 1 Reply Last reply Reply Quote 0. However, a steps/mm value of 5. 4 card. Last edit at 01/11/2023 01:58AM by Dust. M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. Zuletzt am 03. 1 Reply Last reply Reply Quote 0. 3rd print: Layer shift of 3mm at layer 3 starting somewhere at 30x25. Other possible causes are a bad stepper motor or cable. send T0), and enable cold extrusion with M302 P1. Type M301, M302 System Analysis and Measurement Centre M301, M302 System Analysis and Measurement Centre Service Manual. Re: How can I move E steppers? January 11, 2023 02:36AMSo are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. For example you can create a Macro. To test for this, with the power off swap the E0 connector on the Duet with another one e. 5beta2 regarding the 'M302 P1' cold extrusion command. I have to turn the power off and on to reset it. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. config. g. Click to Enlarge. Only users with topic management privileges can see it. If that's not the case, we need to change the direction of rotation. From nozzles to swing pipes, Rain Bird offers a broad range of sprinkler parts and accessories to meet your irrigation needs. 100". Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". Other possible causes are a bad stepper motor or cable. The labels makes it easier for me to get a feel for the group a specific command belongs to, and makes it easy to find commands related to some specific task. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. microswitch) endstop. g: 1. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. M302 P1 M563 P0 D0 T1 ;enable cold extrusion. This topic has been deleted. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. The endstop is connected and is working, the wir.